-40%

TEKTRONIX TDS5054 DIGITAL PHOSPHOR OSCILLOSCOPE with probes, manuals etc

$ 897.07

Availability: 100 in stock
  • Maximum Real-Time Sampling Rate: 5GS/s
  • All returns accepted: ReturnsNotAccepted
  • Number of Channels: 4
  • Maximum Bandwidth: 500 MHz
  • Type: Digital
  • Channels: 4
  • Condition: Used low hours. I am the original owner of this instrument. It's in excellent condition. It has been tested and is guaranteed to be in working condition. It INCLUDES probes, manuals, software, paper and protective cover, most of which are unused. See photos.
  • Model: TDS5054 digital phosphor oscilloscope
  • MPN: TDS5054
  • Brand: Tektronix

    Description

    VINTAGE TEKTRONIX  TDS5054 DIGITAL PHOSPHOR OSCILLOSCOPE
    Used Low Hours
    Oscilloscope purchase includes
    :
    1 power cord, 3 lightly used voltage probes, 1 NEW voltage probe with instructions, 3 NEW unused passive probe kits with instructions, User Manual, reference guide, "Oscilloscope Analysis and Connectivity Made Easy" manual & CD, corresponding MATLAB, LabVIEW software, Product Software, System Restore CD-ROM, CD-R, CD-RW, Click'n Burn CD ROM, printer instructions, printer refill paper (3 rolls of unopened thermal paper), Optional Applications Software on Windows-Based Oscilloscopes, new mouse and hard face cover and soft full cover.
    These are all items that were included in the original sale of this oscilloscope, except the soft cover which I had made.
    See photos for all items included in sale.  This oscilloscope is in full working condition. Please reach out with any questions.
    *******************************
    The Tektronix TDS5054 digital phosphor oscilloscope delivers up to 500 MHz Bandwidth, 5 GS/s real-time sample rate, 2 MB record length and 100,000 wfms/s maximum waveform capture rate. This performance, along with a suite of advanced triggers, intuitive user interface, and an open Windows platform, all in a compact bench-top package, provides exceptional value.
    Digital phosphor oscilloscopes provide insight into signal behavior by displaying, storing and analyzing complex signals in real-time using three dimensions of signal information: amplitude, time and distribution of amplitude over time. This Tektronix TDS5054 delivers fast waveform capture rates, enabled by Tektronix proprietary DPX™ acquisition technology, saving minutes, hours or even days by quickly revealing the nature of faults so sophisticated trigger modes can be applied to isolate them.
    Features:
    Intuitive User Interface for Easy Operation
    Small Footprint
    10.4 in. (264 mm) Bright Display
    Suite of Advanced Triggers
    Interoperability with Tektronix Logic Analyzers
    Applications:
    Digital Design and Debug, Investigation of Transient Phenomena, Power Measurements, Video Design and Debug, DVD Analysis, Disk Drive Analysis, Jitter & Timing Analysis, Spectral Analysis, Automotive Electronics, Manufacturing Test, Electromechanical, Biomedical, Industrial Control.
    Specifications:
    TDS5054 Vertical System
    Input Channels
    4
    Analog Bandwidth (-3 dB) 5 mV/div - 1 V/div
    500 MHz
    Calculated Rise Time 5 mV/div (typical)
    800 ps
    Hardware Bandwidth Limits
    150 MHz or 20 MHz
    Input Coupling
    AC, DC, GND
    Input Impedance, 1 MΩ
    ±1%
    Input Impedance, 50 MΩ
    ±1%
    Input Sensitivity, 1 MΩ
    1 mV/div to 10 V/div
    Input Sensitivity, 50Ω
    1 mV/div to 1 V/div
    Vertical Resolution
    8-bits (>11-bits w/ averaging)
    Max Input Voltage, 1 MΩ
    ±150 V CAT I derate at 20 dB/decade to 9 VRMS above 200 kHz
    Max Input Voltage, 50 Ω
    5 VRMS with peaks <±30 V
    DC Gain Accuracy
    1.5% with offset set to 0 V
    Offset Range, 1 MΩ
    1 mV/div - 99.5 mV/div ±1 V
    100 mV/div - 1 V/div ±10 V
    1.01 V/div - 10 V/div ±100 V
    Offset Range, 50 Ω
    1 mV/div - 99.5 mV/div ±1 V
    100 mV/div -1 V/div ±10 V
    Channel-to-channel Isolation Any Two Channels at Equal Vertical Scale
    ≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth
    TDS5054 Timebase System
    Timebase Range
    200 ps/div to 40 s/div
    Timebase Delay Time Range
    16 ns to 250 s
    Channel-to-channel Deskew Range
    ±75 ns
    Delta Time Measurement Accuracy
    ±(0.30 sample interval) + (15 ppm * reading)
    Trigger Jitter (RMS)
    8 psRMS (typical)
    Long Term Sample Rate and Delay Time Accuracy
    ±15 ppm over ≥1 ms interval
    TDS5054 Acquisition System
    Real-time Sample Rate
    1.25 GS/s
    Equivalent Time Sample Rate (max)
    250 GS/s
    Maximum Record Length per Channel with Standard Memory
    100 k
    With Opt. 1M
    500 k
    With Opt. 2M
    2 M
    TDS5054 Acquisition Modes
    FastAcq Acquisition
    FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events
    Maximum FastAcq Waveform Capture Rate
    100,000 wfms/s
    Sample
    Acquire sampled values
    Peak Detect
    Captures narrow glitches at all real-time sampling rates
    Minimum Peak Detect Pulse Width
    <1 ns
    Averaging
    From 2 to 10,000 waveforms included in average
    Envelope
    From 2 to 2 x 10
    9
    waveforms included in min-max envelope
    Hi-Res
    Real-time boxcar averaging reduces random noise and increases resolution
    FastFrame™ Acquisition
    Acquisition memory divided into segments; maximum trigger rate >225,000 waveforms per second
    TDS5054 Trigger System
    Sensitivity
    Internal DC Coupled:
    0.35 div DC to 50 MHz increasing to 1 div at rated bandwidth
    External (auxiliary input):
    400 mV from DC to 50 MHz increasing to 750 mV at 100 MHz
    Main Trigger Modes:
    Auto, Normal, and Single
    Trigger Sequences:
    Main, Delayed by time, Delayed by events. All sequences can include separate horizontal delay after the trigger event to position the acquisition window in time
    Trigger Level Range
    Internal:
    ±10 divisions from center of screen
    External (auxiliary in):
    ±8 V
    Line:
    Fixed at 0 V
    Trigger Coupling:
    DC, AC (attenuate <60 Hz), HF reject (attenuate >30 kHz)
    LF reject (attenuate <80 kHz) Noise reject (reduce sensitivity)
    Trigger Holdoff Range:
    250 ns minimum to 12 s maximum