-40%

FLUKE PHILIPS PM3094 200 MHZ OSCILLOSCOPE 4 CHANNEL 2 PROBES TESTED WORKING

$ 129.35

Availability: 100 in stock
  • All returns accepted: ReturnsNotAccepted
  • Brand: FLUKE PHILIPS
  • MPN: PM3094
  • Condition: Used condition. Powers up as you can see. Some switches are sticking. Sold for pars or repair only. No return or refund.

    Description

    You are bidding on one FLUKE PHILIPS PM3094 200 MHZ OSCILLOSCOPE 4 CHANNEL with 2 PROBES and power cord. Good used tested working condition. Powers up as you can see. We have 6 and price is for 1 oscilloscope with 2 probes and power cord. 4 have IEE 488 options and 2 don't. Only 4 have the front cover. Backup battery terminals have some corrosion. Batteries are not included. No other parts included. Please look at the pics for details. Sold as is in a pictured described S&h cost to lower 48 states only. International shipping via USPS priority mail paid buy buyer.
    You are bidding on
    one
    FLUKE PHILIPS PM3094 200 MHZ OSCILLOSCOPE 4 CHANNEL with 2 PROBES and power cord
    .
    Good used tested working condition.
    Powers up as you can see.
    We have 3 and price is for 1 oscilloscope with 2 probes and power cord.
    1 have IEE 488 options and 2 don't. Only 1 have the front cover. Backup battery terminals have some corrosion. Batteries are not included. No other parts included. Please look at the pics for details.
    Sold as is in a pictured described
    S&h cost to lower 48 states only.
    International shipping via USPS priority mail paid buy buyer.
    Please E-mail me if you have any questions,
    it is FREE
    .
    DESCRIPTION:
    FLUKE PM3094 Autoset and Autocal Autoset Selects proper channel, time-base and trigger settings. Function can be customized. Autocal Automatic fine adjustment for enhanced accuracy to get optimal performance even under extreme environmental conditions Vertical Deflection Input Channels (PM3084/94): Four fully attenuated channels (PM3082/92): Two fully attenuated channels, plus two limited attenuated channels (2+2). Frequency Response (PM3092/94): DC to > 200 MHz (PM3082/84): DC to > 100 MHz Display Modes CH1, (-)CH2, CH3, (-)CH4, Add: CH1 & (-)CH2, CH3 & (-)CH4 In ALTernate or CHOPped mode. Bandwidth Limiter 20 MHz -3 db All All Rise Time (Calculated) (PM3092/94): < 1.75 ns (PM3082/84): < 3.50 ns Deflection Coefficient CH1 & CH2 (all models): 2 mV/div to 5 V/div in a 1-2-5 Sequence or continuously calibrated control, 2 mV/div to 12.5 V/div Ch3 & Ch4 (PM3082/92): 0.1 V/div and 0.5 V/div only Ch3 & Ch4 (PM3084/94): 2 mV/div to 5 V/div in a 1-2-5 Sequence or continuously calibrated control, 2 mV/div to 12.5 V/div Error Limit 1.3% measured over 6 central vertical divisions. Input Impedance 1 & ±1% // 2 pf and 50& (PM 3094 and CH1 & CH2 of PM 3092) Max. Rated Input Voltage In 1 M& position: 150 Vrms CAT III In 50& position: 5 Vrms; 50 V ac peak (max of 50 m Joules during any 100 ms interval) Horizontal Deflection Display Modes Main TB and/or Delayed TB, X-deflection. Main Time Base Time Coefficients: (PM 3092/94) 0.5 s/div to 20 ns/div in a 1-2-5 sequence, 1.25 s/div to 20 ns/div continuously calibrated control. (PM 3082/84) 0.5 s/div to 50 ns/div in a 1-2-5 sequence, 1.25 s/div to 50 ns/div continuously calibrated control. Error Limit (magn 1X): ±(1.3% of reading + 0.5% of 8 divisions) Hold Off: Up to 20 divisions of MTB setting (max 2 sec) Delayed Time Base Time Coefficients: (PM 3092/94) 0.5 ms/div to 20 ns/div in a 1-2-5 sequence. (PM 3082/84) 0.5 ms/div to 50 ns/div in a 1-2-5 sequence. Fastest Sweep: (PM 3092/94) 2 ns/div (magn 10X) (PM 3082/84) 5 ns/div (magn 10X) Error Limit (magn 1X): ±(1.3% of reading + 0.5% of 8 divisions) Trace Separation: ±34 div Triggering (MTB & DTB) Trigger Modes Auto free run, Triggered, Single, Edge triggering, TV triggering Edge Triggering MTB Trigger Source: CH1 to CH4, Composite, Line(Mains) DTB Trigger Source: CH1 to CH4, TV-Line Slope: Positive or Negative Coupling: DC, AC (10 Hz), Lf-rej (30 kHz), Hf-rej (30 kHz) Level Range: ±8 div or level within signal peak to peak range. Level Indication: On screen level indicators and numeric readout. Trigger Sensitivity: (PM 3092/94) 0.5 div up to 100 MHz, 1.0 div up to 200 MHz, 2.0 div up to 300 MHz (PM 3082/84) ) 0.5 div up to 50 MHz, 1.0 div up to 100 MHz, 2.0 div up to 200 MHz TV Triggering Video Standard: HDTV, NTSC, PAL, SECAM standards MTB Trigger Source: CH1 to CH4, Field1, Field2, TV-Line Signal Polarity: Positive or Negative Sensitivity: 0.7 div (Sync Pulse) X Deflection Deflection Source CH1 to CH4, Line(Mains) Deflection Coefficient See vertical deflection Dynamic Range 20 div up to 100 kHz, > 10 div up to 2 MHz Frequency Response 2 MHz -3db Error Limit 5% measured over central 6 divisions Phase Shift < 3o up to 100 kHz Cursor Measurements Cursor Modes Manual positioning: Horizontal, Vertical, Both Auto Positioning: Vp-p or 10-90% or 20-80% Auto Positioning Vp-p or 10-90% or 20-80% Readout Vertical: dV, V1&V2 to GND, Ratio Horizontal: dt, 1/dt (in Hz), Ratio, Phase Auto Positioning: Vpp, Vp+&Vp- to GND, Vdc and Trise Accuracy (magn 1X) ±1% of full scale. Within the central 8 horizontal and 6 vertical divisions for manual cursor positioning. Interfaces RS 232C 9 Pin D.Connector GPIB/IEEE 488.2 Factory installed option, SCPI Protocol Power Supply Line Voltage 100V to 240V (±10%) CAT II Line Frequency 50 Hz to 400 Hz (±10%) Power Consumption 60W (80W with all options installed) Mechanical Data Size (excluding handle & feet) 139 mm H x 341 mm W x 481 mm L 5.5 in. H x 13.4 in. W x 18.9 in. L Weight 8.5 kg 20 lb.
    Pictures sell!
    Auctiva offers Free Image Hosting and Editing.
    The complete eBay Selling Solution.
    Track Page Views With
    Auctiva's FREE Counter