Fluke 124B Industrial ScopeMeter® Hand-Held Oscilloscope, 40 MHz
It features innovative functions that help technicians troubleshoot faster and obtain the answers they need to keep their systems going. This handheld oscilloscope also allows users to automatically view related numerical measurements due to it's Fluke IntellaSet™ technology. Additionally, it comes with Recorder Event Detect capabilities, which capture intermittent events and logs them for simple viewing and analysis.
Features
Dual-input digital oscilloscope and multimeter
40 MHz oscilloscope bandwidth
Two 5000-count True RMS digital multimeters
Connect-and-View™ trigger simplicity for hands-off operation
IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal
Dual-input waveform and meter reading recorder for trending data over extended periods
Recorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHz
Shielded test leads for oscilloscope, resistance and continuity measurements
Resistance, continuity, diode and capacitance meter measurements
Power measurements (W, VA, VAR, PF, DPF, Hz)
Voltage, current and power harmonics
Check Industrial networks with BusHealth physical layer tests against defined reference levels
Save or recall data and instrument setups
Store instrument setups defined by a test sequence for routine maintenance or most often used test procedures
External optically isolated USB interface to transfer, archive and analyze scope or meter data
Optional WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
FlukeView® ScopeMeter® Software for Windows®
Rugged design to withstand 3g Vibration, 30g shock, and rated IP51 according to EN/IEC60529
Highest safety rating in the industry: safety rated for CAT IV 600 V
Connect-and-View™ triggering for an instant, stable display
Oscilloscope users know how difficult triggering can be. Using the wrong settings can lead to unstable waveform captures, and sometimes the wrong measurement data. This instrument's unique Connect-andView™ triggering technology recognizes signal patterns, and automatically sets up the correct triggering to provide a stable, reliable and repeatable display. Connect-and-View™ triggering is designed to work with virtually any signal, including motor drives and control signals - without adjusting parameters, or even touching a button. Signal changes are instantly recognized and settings are automatically adjusted, providing a stable display even when measuring multiple test points in quick succession.
IntellaSet™/AutoReading
The Auto Readings function with Fluke IntellaSet™ technology uses proprietary algorithms to intelligently analyze the measured waveform and automatically displays the most appropriate numerical measurements on screen, so you can get the data you need easier than ever before. As an example, when the measured waveform is a line voltage signal, the Vrms and Hz readings are automatically displayed, whereas if the measured waveform is a square wave, the peak-peak and Hz readings are automatically displayed. Using IntellaSet™ technology in conjunction with Connect-and-View™ automatic triggering you can be sure you're seeing not only the correct waveform, but the appropriate numerical reading as well. All without touching a button.
Industrial equipment needs a reliable power supply to operate properly, use the dual input to obtain key power measurements
For single phase or 3-phase balanced systems, the dual inputs of the Industrial ScopeMeter® 120B Series can measure AC+DC RMS voltage on channel A and AC+DC RMS current on channel B.
Harmonics measurements
Harmonics are periodic distortions of voltage, current, or power sine waves. Harmonics in power distribution systems are often caused by non-linear loads such as switched mode dc power supplies and adjustable speed motor drives. Harmonics can cause transformers, conductors, and motors to overheat. In the Harmonics function, the Test Tool measures harmonics to the 51st. Related data such as dc components, THD (Total Harmonic Distortion), and K factor are measured to provide a complete insight in to the electrical state of health of your loads.
One test lead to measure multiple electrical parameters
High frequency waveform, meter, capacitance and resistance measurements as well as continuity checks are all covered by single set of shielded test leads. No time is wasted finding or swapping leads.
Fluke Connect mobile app compatibility
Automated industrial machinery is harder than ever to trouble shoot. It's not enough to just know where you have to test, you also have to know what to look for-and that can be hard without baseline measurement data or access to subject matter experts. The Fluke Connect® Assets wireless system of software and wireless test tools enables technicians to reduce maintenance costs and increase uptime with accurate equipment records and maintenance data that is easy to interpret, and share. Compare and contrast test point measurement data and trends so you can better understand signal characteristics and changes over time. And, by storing maintenance data on the Fluke Cloud™ you can enable team members to access it from wherever and whenever they need to so you can get advice or approvals in the field and get your systems up and running faster than ever before.
Use the comprehensive recorder modes to help find intermittent faults with ease
The toughest faults to find are those that happen only once in a while-intermittent events. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. Other factors, like line outages and sags or the starting and stopping of a motor, can also cause intermittent events resulting in equipment shutdowns. When these events happen, you may not be around to see it. But, your Fluke ScopeMeter® Test Tool will. You can either plot the minimum and maximum peak measurement values or record the waveform trace. And, with expandable micro SD memory, recording sessions can be done for up to 14 days. This recorder is even more powerful with the addition of Recorder Event Detect, which makes detecting and logging intermittent faults easier than ever. Just set a threshold on a meter reading or scope trace and deviations are tagged as unique events. You no longer need to search through masses of data to pinpoint faults, and can quickly step from one tagged event to the next, while still having access to the full data set.
Industrial Bus Health Test verifies electrical signal quality on industrial buses
Bus Health Test analyzes the electrical signals on the industrial bus or network and gives a clear "Good", "Weak" or "Bad" indication mark for each of the relevant parameters, presented next to the actual measurement value. Measured values are compared to standard values based on the selected bus types (CAN-bus, Profi-bus, Foundation Field, RS-232 and many more), or, unique reference values can be set if different tolerances are required.
Included
Oscilloscope
2 x Shielded Test Leads with Ground Leads
Test Lead
Hook Clips
Banana to BNC Adapter
Voltage Probe
USB Angled Adapter
WiFi USB Adapter
Li-Ion Battery Pack
Charger/Power Adapter
Specifications
Oscilloscope Mode - Vertical
Frequency Response - DC Coupled
Without probes and test leads (with BB120): DC to 40 MHz (-3 dB)
With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB)/DC to 20 MHz (-6 dB)
With VP41 10:1 Probe: DC to 40 MHz (-3 dB)
Frequency Response - AC Coupled (LF Roll Off)
Without probes and test leads: <10 Hz (-3 dB)
With STL120-IV 1:1 shielded test leads: <10 Hz (-3 dB)
With VP41 10:1 Probe: <10 Hz (-3 dB)
Rise Time, Excluding Probes, Test Leads
<8.75 ns
Input Impedance
Without probes and test leads: 1 M&ohm//20 pF
With BB120: 1 M&ohm//24 pF
With STL120-IV 1:1 shielded test leads: 1 M&ohm//230 pF
With VP41 10:1 Probe: 5 M&ohm//15.5 pF
Sensitivity
5 mV to 200 V/div
Analog Bandwidth Limiter
10 kHz
Display Modes
A, -A, B, -B
Maximum Input Voltage A and B
Direct, with test leads, or with VP41 Probe: 600 Vrms Cat IV, 750 Vrms maximum voltage
With BB120: 600 Vrms
Maximum Floating Voltage, From any Terminal to Ground
600 Vrms Cat IV, 750 Vrms up to 400 Hz
Oscilloscope Mode - Horizontal
Scope Modes
Normal, Single, Roll
Ranges (Normal)
Equivalent sampling: 10 to 500 ns/div
Real time sampling: 1 µs to 5 s/div
Single (real time): 1 µs to 5 s/div
Roll (real time): 1s to 60 s/div
Sampling Rate (For Both Channels Simultaneously)
Equivalent sampling (repetitive signals): Up to 4 GS/s
Real time sampling 1 µs to 60 s/div: 40 MS/s
Trigger
Screen Update
Free run, on trigger
Source
A, B
Sensitivity A and B
At DC to 5 MHz: 0.5 divisions or 5 mV
At 40 MHz: 1.5 divisions
At 60 MHz: 4 divisions
Slope
Positive, negative
Advanced Scope Functions
Display Modes - Normal
Captures up to 25 ns glitches and displays analog-like persistence waveform
Display Modes - Smooth
Suppresses noise from a waveform
Display Modes - Glitch Off
Does not capture glitches between samples
Display Modes - Envelope
Records and displays the minimum and maximum of waveforms over time
Auto Set (Connect-and-View™)
Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.
DC Voltage (VDC)
Ranges
500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy
±(0.5% +5 counts)
Common Mode Rejection (CMRR)
>100 dB at DC
>60 dB at 50, 60, or 400 Hz
Full Scale Reading
5000 counts
True RMS Voltages (V AC and V AC/DC)
Ranges
500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy for 5 to 100% of Range (DC Coupled)
DC to 60 Hz (V AC/DC): ±(1% +10 counts)
1 to 60 Hz (V AC): ±(1% +10 counts)
Accuracy for 5 to 100% of Range (AC or DC Coupled)
60 Hz to 20 kHz: ±(2.5% +15 counts)
DC Rejection (Only VAC)
>50 dB
Common Mode Rejection (CMRR)
>100 dB at DC
>60 dB at 50, 60, or 400 Hz
Full Scale Reading
5000 counts, reading is independent of any signal crest factor
Peak
Modes
Max peak, Min peak, or pk-to-pk
Ranges
500 mV, 5 V, 50 V, 500 V, 2200 V
Accuracy
Accuracy Max peak or Min peak: 5% of full scale
Accuracy Peak-to-Peak: 10% of full scale
Full Scale Reading
500 counts
Frequency (Hz)
Ranges
1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz
Frequency Range
15 Hz (1 Hz) to 50 MHz in continuous autoset
Accuracy at 1 Hz to 1 MHz
±(0.5% +2 counts)
Full Scale Reading
10,000 counts
RPM
Maximum Reading
50.00 kRPM
Accuracy
±(0.5% +2 counts)
Duty Cycle (PULSE)
Range
2 to 98%
Frequency Range
15 Hz (1 Hz) to 30 MHz in continuous autoset
Pulse Width (PULSE)
Frequency Range
15 Hz (1 Hz) to 30 MHz in continuous autoset
Full Scale Reading
1000 counts
Amperes (AMP)
With Current Clamp
Ranges: Same as V dc, V ac, V ac+dc, or PEAK
Scale factors: 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA
Accuracy: Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)
Temperature (TEMP) with Optional Temperature Probe
Range
200°F/div (200°C/div)
Scale Factor
1 mV/°F and 1 mV/°C
Accuracy
As V dc (add temp. probe uncertainty)
Decibel (dB)
0 dBV
1 V
0 dBm (600 &ohm/50 &ohm)
1 mW referenced to 600 &ohm or 50 &ohm
dB on
V DC, V AC, or V AC+DC
Full Scale Reading
1000 counts
Crest Factor (CREST)
Range
1 to 10
Full Scale Reading
90 Counts
Phase
Modes
A to B, B to A
Range
0 to 359°
Resolution
1°
Vpwm
Purpose
To measure on pulse width modulated signals, like motor drive inverter outputs
Principle
Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
Accuracy
As Vrms for sinewave signals
Input A to Common - (&ohm)
Ranges
500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy
±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)
Full Scale Reading
50 Ω to 5 MΩ at 5000 counts, 30 MΩ at 3000 counts
Measurement Current
0.5 mA to 50 nA, decreases with increasing ranges
Open Circuit Voltage
<4 V
Continuity (Cont)
Beep
<(30 Ω ±5 Ω) in 50 Ω range
Measurement Current
0.5 mA
Detection of Shorts of
≥1 ms
Diode
Measurement Voltage
At 0.5 mA: >2.8 V
At open circuit: <4 V
Measurement Current
0.5 mA
Polarity
+ on input A, - on COM
Capacitance (CAP)
Ranges
50 nF, 500 nF, 5 µF, 50 µF, 500 µF
Full Scale Reading
5000 counts
Measurement Current
500 nA to 0.5 mA, increases with increasing ranges
Advanced Meter Functions
Zero Set
Set actual value to reference
AutoHold (on A)
Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
Fixed Decimal Point
Activated by using attenuation keys
Cursor Readout
Sources
A, B
Single Vertical Line
Average, min and max readout
Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD)
Min, max and time from start of readout (in RECORDER mode; instrument in HOLD)
Harmonics values in POWER QUALITY mode.
Dual Vertical Lines
Peak-peak, time distance and reciprocal time distance readout
Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
Dual Horizontal Lines
High, low and peak-peak readout
Rise or Fall Time
Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only possible in single channel mode)
Accuracy
As oscilloscope accuracy
Meter Readings
Measurement Speed
Maximum 2 measurement/s
Record Size (Min, Max, Average)
2 M readings for 1 channel
Recorded Time Span
2 weeks
Maximum Number of Events
1024
Waveform Record
Maximum Sample Rate
400 K sample/s
Size Internal Memory
400 M samples Recorded Time
Span Internal Memory
15 minutes at 500 µs/div
11 hours at 20 ms/div
Record Size SD Card
1.5 G samples
Recorded Time Span SD Card
11 hours at 500 µs/div
14 days at 20 ms/div
Maximum number of Events
64
Miscellaneous
Display
Type: 5.7" color active matrix TFT
Resolution: 640 x 480 pixels
Waveform Display
Vertical: 10 div of 40 pixels
Horizontal: 12 div of 40 pixels
Power
External: Via Power Adapter BC430
Input voltage: 10 to 21 V DC
Power consumption: 5 W typical
Input connector: 5 mm jack
Internal: Via Battery Pack BP290
Battery power: Rechargeable Li-Ion 10.8 V
Operating time: 7 hours with 50% backlight brightness
Charging time: 4 hours with test tool off, 7 hours with test tool on
Allowable ambient temperature: 32 to 104°F (0 to 40°C) during charging
Memory
Internal memory can store 20 data sets (screen waveform and setup)
Micro SD card slot with optional SD card (max size of 32 GB)
Interface
Optically Isolated
Transfer screen copies (bitmaps), settings and data
USB to PC/Laptop
OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®.
Optional WiFi Adapter
Fast transfer of screen copies (bitmaps), settings and data to PC/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.
General Specifications
Environmental
MIL-PRF-28800F, Class 2
Temperature
Battery Operation: 32 to 104°F (0 to 40°C)
Power Adapter Operation: 32 to 122°F (0 to 50°C)
Storage: -4 to 140°F (-20 to 60°C)
Humidity (Operating)
Non-condensing at 32 to 50°F (0 to 10°C)
95% at 50 to 86°F (10 to 30°C)
75% at 86 to 104°F (30 to 40°C)
45% at 104 to 122°F (40 to 50°C)
Storage
Non-condensing at -4 to 140°F (-20 to 60°C)
Altitude
Operating at 10,000' (3 km): CAT III 600 V
Operating at 6600' (2 km): CAT IV 600 V
Storage: 40,000' (12 km)
Wireless Radio with Adapter
Frequency Range: 2412 to 2462 MHz
Output power: <100 mW
Maximum input voltage input A and B
Direct on input or with leads: 600 Vrms CAT IV for derating
With Banana-to-BNC Adapter BB120: 600 Vrms for derating
Maximum floating voltage from any terminal to ground: 600 Vrms Cat IV, 750 Vrms up to 400 Hz
Dimensions
10.2 x 5.2 x 2.15" (259 x 132 x 55 mm)
Weight
3.2 lbs (1.4 kg)
Safety
General: IEC 61010-1: Pollution Degree 2
Measurement: IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
Enclosure Protection
IP51, ref: EN/IEC60529
Terms & Conditions
Item Condition:
Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
Shipping:
We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
*Shipping Rates are for Continental US, Please Contact us for other US Destinations
Payment:
Currently all payments must be made directly though PayPal
Sales Tax:
We are required to charge sales tax in North Carolina
Return Policy:
If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.