Fluke 124B Industrial ScopeMeter® Hand-Held Oscilloscope, 40 MHz

$ 1203.83

Availability: 100 in stock
  • MPN: 124B
  • Return shipping will be paid by: Seller
  • Condition: New
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • Model: 124B
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Brand: Fluke

    Description

    Untitled Document
    Fluke 124B Industrial ScopeMeter® Hand-Held Oscilloscope, 40 MHz
    Model:
    124B
    | Order No:
    124B/NA
    Features a 40 MHz bandwidth, this hand-held oscilloscope is ideal for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. This instrument integrates an oscilloscope, multimeter, and high-speed recorder. Additionally, it is Fluke Connect compatible.
    Brand:
    Fluke
    Model:
    124B
    Order No:
    124B/NA
    Condition:
    NEW
    Description
    Fluke 124B Industrial ScopeMeter® Hand-Held Oscilloscope, 40 MHz
    It features innovative functions that help technicians troubleshoot faster and obtain the answers they need to keep their systems going. This handheld oscilloscope also allows users to automatically view related numerical measurements due to it's Fluke IntellaSet™ technology. Additionally, it comes with Recorder Event Detect capabilities, which capture intermittent events and logs them for simple viewing and analysis.
    Features
    Dual-input digital oscilloscope and multimeter
    40 MHz oscilloscope bandwidth
    Two 5000-count True RMS digital multimeters
    Connect-and-View™ trigger simplicity for hands-off operation
    IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal
    Dual-input waveform and meter reading recorder for trending data over extended periods
    Recorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHz
    Shielded test leads for oscilloscope, resistance and continuity measurements
    Resistance, continuity, diode and capacitance meter measurements
    Power measurements (W, VA, VAR, PF, DPF, Hz)
    Voltage, current and power harmonics
    Check Industrial networks with BusHealth physical layer tests against defined reference levels
    Save or recall data and instrument setups
    Store instrument setups defined by a test sequence for routine maintenance or most often used test procedures
    External optically isolated USB interface to transfer, archive and analyze scope or meter data
    Optional WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
    FlukeView® ScopeMeter® Software for Windows®
    Rugged design to withstand 3g Vibration, 30g shock, and rated IP51 according to EN/IEC60529
    Highest safety rating in the industry: safety rated for CAT IV 600 V
    Connect-and-View™ triggering for an instant, stable display
    Oscilloscope users know how difficult triggering can be. Using the wrong settings can lead to unstable waveform captures, and sometimes the wrong measurement data. This instrument's unique Connect-andView™ triggering technology recognizes signal patterns, and automatically sets up the correct triggering to provide a stable, reliable and repeatable display. Connect-and-View™ triggering is designed to work with virtually any signal, including motor drives and control signals - without adjusting parameters, or even touching a button. Signal changes are instantly recognized and settings are automatically adjusted, providing a stable display even when measuring multiple test points in quick succession.
    IntellaSet™/AutoReading
    The Auto Readings function with Fluke IntellaSet™ technology uses proprietary algorithms to intelligently analyze the measured waveform and automatically displays the most appropriate numerical measurements on screen, so you can get the data you need easier than ever before. As an example, when the measured waveform is a line voltage signal, the Vrms and Hz readings are automatically displayed, whereas if the measured waveform is a square wave, the peak-peak and Hz readings are automatically displayed. Using IntellaSet™ technology in conjunction with Connect-and-View™ automatic triggering you can be sure you're seeing not only the correct waveform, but the appropriate numerical reading as well. All without touching a button.
    Industrial equipment needs a reliable power supply to operate properly, use the dual input to obtain key power measurements
    For single phase or 3-phase balanced systems, the dual inputs of the Industrial ScopeMeter® 120B Series can measure AC+DC RMS voltage on channel A and AC+DC RMS current on channel B.
    Harmonics measurements
    Harmonics are periodic distortions of voltage, current, or power sine waves. Harmonics in power distribution systems are often caused by non-linear loads such as switched mode dc power supplies and adjustable speed motor drives. Harmonics can cause transformers, conductors, and motors to overheat. In the Harmonics function, the Test Tool measures harmonics to the 51st. Related data such as dc components, THD (Total Harmonic Distortion), and K factor are measured to provide a complete insight in to the electrical state of health of your loads.
    One test lead to measure multiple electrical parameters
    High frequency waveform, meter, capacitance and resistance measurements as well as continuity checks are all covered by single set of shielded test leads. No time is wasted finding or swapping leads.
    Fluke Connect mobile app compatibility
    Automated industrial machinery is harder than ever to trouble shoot. It's not enough to just know where you have to test, you also have to know what to look for-and that can be hard without baseline measurement data or access to subject matter experts. The Fluke Connect® Assets wireless system of software and wireless test tools enables technicians to reduce maintenance costs and increase uptime with accurate equipment records and maintenance data that is easy to interpret, and share. Compare and contrast test point measurement data and trends so you can better understand signal characteristics and changes over time. And, by storing maintenance data on the Fluke Cloud™ you can enable team members to access it from wherever and whenever they need to so you can get advice or approvals in the field and get your systems up and running faster than ever before.
    Use the comprehensive recorder modes to help find intermittent faults with ease
    The toughest faults to find are those that happen only once in a while-intermittent events. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. Other factors, like line outages and sags or the starting and stopping of a motor, can also cause intermittent events resulting in equipment shutdowns. When these events happen, you may not be around to see it. But, your Fluke ScopeMeter® Test Tool will. You can either plot the minimum and maximum peak measurement values or record the waveform trace. And, with expandable micro SD memory, recording sessions can be done for up to 14 days. This recorder is even more powerful with the addition of Recorder Event Detect, which makes detecting and logging intermittent faults easier than ever. Just set a threshold on a meter reading or scope trace and deviations are tagged as unique events. You no longer need to search through masses of data to pinpoint faults, and can quickly step from one tagged event to the next, while still having access to the full data set.
    Industrial Bus Health Test verifies electrical signal quality on industrial buses
    Bus Health Test analyzes the electrical signals on the industrial bus or network and gives a clear "Good", "Weak" or "Bad" indication mark for each of the relevant parameters, presented next to the actual measurement value. Measured values are compared to standard values based on the selected bus types (CAN-bus, Profi-bus, Foundation Field, RS-232 and many more), or, unique reference values can be set if different tolerances are required.
    Included
    Oscilloscope
    2 x Shielded Test Leads with Ground Leads
    Test Lead
    Hook Clips
    Banana to BNC Adapter
    Voltage Probe
    USB Angled Adapter
    WiFi USB Adapter
    Li-Ion Battery Pack
    Charger/Power Adapter
    Specifications
    Oscilloscope Mode - Vertical
    Frequency Response - DC Coupled
    Without probes and test leads (with BB120): DC to 40 MHz (-3 dB)
    With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB)/DC to 20 MHz (-6 dB)
    With VP41 10:1 Probe: DC to 40 MHz (-3 dB)
    Frequency Response - AC Coupled (LF Roll Off)
    Without probes and test leads: <10 Hz (-3 dB)
    With STL120-IV 1:1 shielded test leads: <10 Hz (-3 dB)
    With VP41 10:1 Probe: <10 Hz (-3 dB)
    Rise Time, Excluding Probes, Test Leads
    <8.75 ns
    Input Impedance
    Without probes and test leads: 1 M&ohm//20 pF
    With BB120: 1 M&ohm//24 pF
    With STL120-IV 1:1 shielded test leads: 1 M&ohm//230 pF
    With VP41 10:1 Probe: 5 M&ohm//15.5 pF
    Sensitivity
    5 mV to 200 V/div
    Analog Bandwidth Limiter
    10 kHz
    Display Modes
    A, -A, B, -B
    Maximum Input Voltage A and B
    Direct, with test leads, or with VP41 Probe: 600 Vrms Cat IV, 750 Vrms maximum voltage
    With BB120: 600 Vrms
    Maximum Floating Voltage, From any Terminal to Ground
    600 Vrms Cat IV, 750 Vrms up to 400 Hz
    Oscilloscope Mode - Horizontal
    Scope Modes
    Normal, Single, Roll
    Ranges (Normal)
    Equivalent sampling: 10 to 500 ns/div
    Real time sampling: 1 µs to 5 s/div
    Single (real time): 1 µs to 5 s/div
    Roll (real time): 1s to 60 s/div
    Sampling Rate (For Both Channels Simultaneously)
    Equivalent sampling (repetitive signals): Up to 4 GS/s
    Real time sampling 1 µs to 60 s/div: 40 MS/s
    Trigger
    Screen Update
    Free run, on trigger
    Source
    A, B
    Sensitivity A and B
    At DC to 5 MHz: 0.5 divisions or 5 mV
    At 40 MHz: 1.5 divisions
    At 60 MHz: 4 divisions
    Slope
    Positive, negative
    Advanced Scope Functions
    Display Modes - Normal
    Captures up to 25 ns glitches and displays analog-like persistence waveform
    Display Modes - Smooth
    Suppresses noise from a waveform
    Display Modes - Glitch Off
    Does not capture glitches between samples
    Display Modes - Envelope
    Records and displays the minimum and maximum of waveforms over time
    Auto Set (Connect-and-View™)
    Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.
    DC Voltage (VDC)
    Ranges
    500 mV, 5 V, 50 V, 500 V, 750 V
    Accuracy
    ±(0.5% +5 counts)
    Common Mode Rejection (CMRR)
    >100 dB at DC
    >60 dB at 50, 60, or 400 Hz
    Full Scale Reading
    5000 counts
    True RMS Voltages (V AC and V AC/DC)
    Ranges
    500 mV, 5 V, 50 V, 500 V, 750 V
    Accuracy for 5 to 100% of Range (DC Coupled)
    DC to 60 Hz (V AC/DC): ±(1% +10 counts)
    1 to 60 Hz (V AC): ±(1% +10 counts)
    Accuracy for 5 to 100% of Range (AC or DC Coupled)
    60 Hz to 20 kHz: ±(2.5% +15 counts)
    DC Rejection (Only VAC)
    >50 dB
    Common Mode Rejection (CMRR)
    >100 dB at DC
    >60 dB at 50, 60, or 400 Hz
    Full Scale Reading
    5000 counts, reading is independent of any signal crest factor
    Peak
    Modes
    Max peak, Min peak, or pk-to-pk
    Ranges
    500 mV, 5 V, 50 V, 500 V, 2200 V
    Accuracy
    Accuracy Max peak or Min peak: 5% of full scale
    Accuracy Peak-to-Peak: 10% of full scale
    Full Scale Reading
    500 counts
    Frequency (Hz)
    Ranges
    1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz
    Frequency Range
    15 Hz (1 Hz) to 50 MHz in continuous autoset
    Accuracy at 1 Hz to 1 MHz
    ±(0.5% +2 counts)
    Full Scale Reading
    10,000 counts
    RPM
    Maximum Reading
    50.00 kRPM
    Accuracy
    ±(0.5% +2 counts)
    Duty Cycle (PULSE)
    Range
    2 to 98%
    Frequency Range
    15 Hz (1 Hz) to 30 MHz in continuous autoset
    Pulse Width (PULSE)
    Frequency Range
    15 Hz (1 Hz) to 30 MHz in continuous autoset
    Full Scale Reading
    1000 counts
    Amperes (AMP)
    With Current Clamp
    Ranges: Same as V dc, V ac, V ac+dc, or PEAK
    Scale factors: 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA
    Accuracy: Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)
    Temperature (TEMP) with Optional Temperature Probe
    Range
    200°F/div (200°C/div)
    Scale Factor
    1 mV/°F and 1 mV/°C
    Accuracy
    As V dc (add temp. probe uncertainty)
    Decibel (dB)
    0 dBV
    1 V
    0 dBm (600 &ohm/50 &ohm)
    1 mW referenced to 600 &ohm or 50 &ohm
    dB on
    V DC, V AC, or V AC+DC
    Full Scale Reading
    1000 counts
    Crest Factor (CREST)
    Range
    1 to 10
    Full Scale Reading
    90 Counts
    Phase
    Modes
    A to B, B to A
    Range
    0 to 359°
    Resolution

    Vpwm
    Purpose
    To measure on pulse width modulated signals, like motor drive inverter outputs
    Principle
    Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
    Accuracy
    As Vrms for sinewave signals
    Input A to Common - (&ohm)
    Ranges
    500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
    Accuracy
    ±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)
    Full Scale Reading
    50 Ω to 5 MΩ at 5000 counts, 30 MΩ at 3000 counts
    Measurement Current
    0.5 mA to 50 nA, decreases with increasing ranges
    Open Circuit Voltage
    <4 V
    Continuity (Cont)
    Beep
    <(30 Ω ±5 Ω) in 50 Ω range
    Measurement Current
    0.5 mA
    Detection of Shorts of
    ≥1 ms
    Diode
    Measurement Voltage
    At 0.5 mA: >2.8 V
    At open circuit: <4 V
    Measurement Current
    0.5 mA
    Polarity
    + on input A, - on COM
    Capacitance (CAP)
    Ranges
    50 nF, 500 nF, 5 µF, 50 µF, 500 µF
    Full Scale Reading
    5000 counts
    Measurement Current
    500 nA to 0.5 mA, increases with increasing ranges
    Advanced Meter Functions
    Zero Set
    Set actual value to reference
    AutoHold (on A)
    Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
    Fixed Decimal Point
    Activated by using attenuation keys
    Cursor Readout
    Sources
    A, B
    Single Vertical Line
    Average, min and max readout
    Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD)
    Min, max and time from start of readout (in RECORDER mode; instrument in HOLD)
    Harmonics values in POWER QUALITY mode.
    Dual Vertical Lines
    Peak-peak, time distance and reciprocal time distance readout
    Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
    Dual Horizontal Lines
    High, low and peak-peak readout
    Rise or Fall Time
    Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only possible in single channel mode)
    Accuracy
    As oscilloscope accuracy
    Meter Readings
    Measurement Speed
    Maximum 2 measurement/s
    Record Size (Min, Max, Average)
    2 M readings for 1 channel
    Recorded Time Span
    2 weeks
    Maximum Number of Events
    1024
    Waveform Record
    Maximum Sample Rate
    400 K sample/s
    Size Internal Memory
    400 M samples Recorded Time
    Span Internal Memory
    15 minutes at 500 µs/div
    11 hours at 20 ms/div
    Record Size SD Card
    1.5 G samples
    Recorded Time Span SD Card
    11 hours at 500 µs/div
    14 days at 20 ms/div
    Maximum number of Events
    64
    Miscellaneous
    Display
    Type: 5.7" color active matrix TFT
    Resolution: 640 x 480 pixels
    Waveform Display
    Vertical: 10 div of 40 pixels
    Horizontal: 12 div of 40 pixels
    Power
    External: Via Power Adapter BC430
    Input voltage: 10 to 21 V DC
    Power consumption: 5 W typical
    Input connector: 5 mm jack
    Internal: Via Battery Pack BP290
    Battery power: Rechargeable Li-Ion 10.8 V
    Operating time: 7 hours with 50% backlight brightness
    Charging time: 4 hours with test tool off, 7 hours with test tool on
    Allowable ambient temperature: 32 to 104°F (0 to 40°C) during charging
    Memory
    Internal memory can store 20 data sets (screen waveform and setup)
    Micro SD card slot with optional SD card (max size of 32 GB)
    Interface
    Optically Isolated
    Transfer screen copies (bitmaps), settings and data
    USB to PC/Laptop
    OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®.
    Optional WiFi Adapter
    Fast transfer of screen copies (bitmaps), settings and data to PC/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.
    General Specifications
    Environmental
    MIL-PRF-28800F, Class 2
    Temperature
    Battery Operation: 32 to 104°F (0 to 40°C)
    Power Adapter Operation: 32 to 122°F (0 to 50°C)
    Storage: -4 to 140°F (-20 to 60°C)
    Humidity (Operating)
    Non-condensing at 32 to 50°F (0 to 10°C)
    95% at 50 to 86°F (10 to 30°C)
    75% at 86 to 104°F (30 to 40°C)
    45% at 104 to 122°F (40 to 50°C)
    Storage
    Non-condensing at -4 to 140°F (-20 to 60°C)
    Altitude
    Operating at 10,000' (3 km): CAT III 600 V
    Operating at 6600' (2 km): CAT IV 600 V
    Storage: 40,000' (12 km)
    Wireless Radio with Adapter
    Frequency Range: 2412 to 2462 MHz
    Output power: <100 mW
    Maximum input voltage input A and B
    Direct on input or with leads: 600 Vrms CAT IV for derating
    With Banana-to-BNC Adapter BB120: 600 Vrms for derating
    Maximum floating voltage from any terminal to ground: 600 Vrms Cat IV, 750 Vrms up to 400 Hz
    Dimensions
    10.2 x 5.2 x 2.15" (259 x 132 x 55 mm)
    Weight
    3.2 lbs (1.4 kg)
    Safety
    General: IEC 61010-1: Pollution Degree 2
    Measurement: IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
    Enclosure Protection
    IP51, ref: EN/IEC60529
    Terms & Conditions
    Item Condition:
    Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
    Shipping:
    We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
    Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
    *Shipping Rates are for Continental US, Please Contact us for other US Destinations
    Payment:
    Currently all payments must be made directly though PayPal
    Sales Tax:
    We are required to charge sales tax in North Carolina
    Return Policy:
    If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
    Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.